ANALOG OSCILLOSCOPE

20MHz Dual Trace Oscilloscope - Model 3702
(with Component Tester)
  Elegant
  DC to 20MHz Bandwidth
  1mV/div Sensitivity on Both Channels
  CH1 & CH2 Independent Channels
  CH1 or CH2 Trigger Signal Output
  Algebraic Addition and Subtraction
  X-Y Operation
  10ns/div to 0.2s/div Time Base
  Z Modulation TTL Level
  8 x 10 cm Display Internal Graticule
  TV Triggering Frame (V) & Line (H)
  Line Trigger
  ALT Triggering
  Trigger Lock Facility
  Single Sweep
  Variable Hold Off
  Component Tester
20MHz Dual Trace Oscilloscope with Component Tester                      

20MHz Dual Trace Oscilloscope - Model 3305S
(with Component Tester)
  DC - 20MHz Bandwidth
  1mV/div Sensitivity on Both Channels
  CH1, CH2 (Independent Channels), CH1 & CH2 (Alternate /  CHOP), CH2 INVT, ADD and SUBTRACT
  X-Y Operation
  40ns/div to 0.2s/div Time Base
  140mm Rectangular CRT with Internal Graticule
  Triggering to 40MHz
  Z Modulation (TTL Level)
  8 x 10 cm Display
  TV Triggering Frame (V) & Line (H)
  Line Trigger
  Component Tester
20MHz Dual Trace Oscilloscope                  

30MHz Dual Trace Oscilloscope with Component Tester - Model 3706C
  DC - 30MHz Bandwidth
  1mV/div Sensitivity on Both Channels
  CH1, CH2 (Independent Channels), CH1 & CH2 (Alternate / CHOP), CH2 INVT, ADD and SUBTRACT
  X-Y Operation
  40ns/div to 0.2s/div Time Base
  140mm Rectangular CRT with Internal Graticule
  Triggering to 40MHz
  Z Modulation (TTL Level)
  8 x 10 cm. Display
  TV Triggering Frame (V) & Line (H)
  MAINS Trigger
  Variable Hold Off
  Built-in Component Tester / Comparator
30MHz Dual Trace Oscilloscope with Component Tester               

25MHz, 30MHz and 60MHz Analog Oscilloscope -
Model 3802 / 3803 / 3806
  Download Catalogue
3802,
3803,3806
  1mV/div Sensitivity on Both Channels
  CH1 & CH2 Independent Channels
  CH1 Signal Output
  Algebraic Addition and Subtraction
  X-Y Operation
  20ns/div to 0.2s/div Time Base
  ALT MAG. Trace - Max. 4 Traces
  Scale Illumination
  Z Modulation
  8 x 10 cm Display Internal Graticule
  Auto Focus
  TV Triggering Frame (V) & Line (H)
  Line Trigger
  ALT Triggering
  C.T. Facility
25MHz, 30MHz, 40MHz and 60MHz  2 Channel 4 Trace Oscilloscope               

100MHz 2 Channel 4 Trace Delayed Sweep Oscilloscope -
Model 3810SD
  Surface Mounting Technology
  DC to 100MHz Bandwidth
  1mV/div Sensitivity on Both Channels
  CH1 & CH2 Independent Channels
  Algebraic Addition and Subtraction
  X-Y Operation
  5ns/div to 0.2s/div Time Base
  A ALT B SWEEPS - Max. 4 Traces
  A and B Delayed Sweep
  HOLD-OFF Time Adjustable
  Scale Illumination
  Z Modulation
  8 x 10 cm Display Internal Graticule
  Auto Focus
  TV Triggering Frame (V) & Line (H)
  Line Trigger
100MHz 2 Channel 4 Trace Delayed Sweep Oscilloscope